Connecting the motor, 16 bluac5-si hardware manual – Applied Motion BLuAC5-Si User Manual

Page 16

Advertising
background image

16

BLuAC5-Si Hardware Manual

920-0035E
12/10/2014

Connecting the Motor

WARNING: Never connect or disconnect the motor while the power is on.

Applied Motion Products motor:
To connect an Applied Motion servo motor to your BLU Servo, you’ll need a set of mating
cables designated BLUENC and BLUMTR-FA.

You must use the “FA” (filtered) motor cable for proper operation of the drive. The
green wire of the cable must be connected to the chassis ground screw of the BLUAC5.

Connect the small motor connector to one end of
the motor cable. The other end of the BLUMTR-
FA has lead wires that connect to the drive’s screw
terminal connector as follows:
A = red wire
B = white wire
C = black wire
Connect the green wire to the chassis ground screw.

Connect the large motor connector to one end of
the BLUENC cable. The other end of the BLUENC
plugs into the BLU servo.

For J-Series motors, use 3004-301-3M and 3004-307-3M cables (one of each).

Non-Applied Motion motor:
Connect the motor leads to the screw terminal connector as follows:
A = motor phase A, R or U
B = motor phase B, S or V
C = motor phase C, T or W
Connect the ground wire to the chassis ground screw.

For proper drive operation, you must use a well shielded, properly grounded cable. Ferrite
filtering is highly recommended and is essential if your application is intended to comply with
EMC directives such as the CE Mark. Please contact Applied Motion Products for technical
advice before connecting a non-Applied Motion motor.

Advertising