Alarm codes connector diagrams, Applied motion products, inc – Applied Motion BLuDC4-Si User Manual

Page 26

Advertising
background image

Alarm Codes

In the event of an error, the green LED on the main board will flash one or two times, followed by a series of red flashes. The
pattern repeats until the alarm is cleared.
Code

Code

Code

Code

Code

Error

Error

Error

Error

Error

1 red, 1 green

position error exceeds fault limit

2 red, 1 green

ccw limit

2 red, 2 green

cw limit

3 red, 1 green

drive internal temperature exceeds 85°C

3 red, 2 green

motor over temperature

4 red, 1 green

power supply voltage is more than 55 VDC

4 red, 2 green

power supply voltage is less than 18 VDC

5 red, 1 green

over current / short circuit

6 red, 1 green

bad commutation(Hall) signal

6 red, 2 green

bad encoder signal

7 red, 1 green

serial communication error

Connector Diagrams

Applied Motion Products, Inc.

404 Westridge Drive Watsonville, CA 95076

Tel (831) 761-6555 (800) 525-1609 Fax (831) 761-6544

www.appliedmotionproducts.com