3.2.2. MAINS SUPPLY
Required mains supply network configuration
3-phase 120 V plus neutral, ~ 60 Hz - 30 A

max.

The X5336 Mains power distributor is supplied with a fixed 3-

phase power cord equipped with a 30 A NEMA L21-30 mains

connector.

3.3. Front panel

3.3.1. MAINS

When the rack is connected to the onsite mains power supply, the

three mains indicators display the presence of the onsite mains

supply lines (phase conductor L1-L2-L3).

3.3.2. AUXILIARY MAINS OUTPUTS 16 A

Three auxiliary mains outputs (powerCON sockets) are provided.

One socket is mounted on the front and two sockets on the rear

panel. They are intended for the connection of low current devices

such as notebooks or additional Ethernet switches.

Each socket can be switched on and off by its dedicated switch.

These switches also serve as circuit-breakers for the corresponding

socket.

Please refer to the switch assignment as shown in the graphic

opposite.

d&b Z5330.050 Manual 1.1 en