4.3 Wizard - Third Step

Figure 6: Wizard Window - Third Step

1. Make sure to stop the last clip played.

2. Load and play the clip “FS Peak White 3D” again (see instructions above on how to play it).

3. With your Spectroradiometer/Colorimeter, measure the luminance of the white for both the

left and right eye and enter them in the wizard.

4. Once both measurements have been entered, the wizard enables the Finish button. Click

the Finish button to complete the procedure.

The calibration procedure is now complete.