9

1

2

3

4

5

6

7

8

PIN 1: IN

PIN 6: OUT

PIN 3&4: GROUND

PIN 2: IN

PIN 3: OUT

PIN 5: GROUND

pins

6

1

Sheet 16 of 18

ISSUE: 011

www.futureautomation.co.uk

FUTUREAUTOMATION

MLS

Marine Lift Swivel Mechanism

Instruction Sheet

RS232

Use an RJ11 connector in the

socket marked RS232 on the

control box to operate using RS232.

DETAILS
Baud rate: 9600

Stop bit: 1

Parity: None

Databits: 8

PROTOCOL
ASCI Command

fa_in = Device IN

fa_out = Device UP only

fa_stop = Device STOP
fa_store = STORE MEMORY position

fa_preset = Go to MEMORY position
fa_home = Device UP only

fa_right = Device UP and to RIGHT limit

fa_left = Device UP and to LEFT limit
ALL COMMANDS FOLLOWED BY

CARRIAGE RUTURN