In

st

al

la

ti

o

n

:

E

le

ct

ric

al

c

on

ne

ct

io

n

Page 17 of 22 // email [email protected] tel: +44 (0) 1438 833577 fax: +44 (0) 1438 833565

QA2 & QA2-60 - Quad Arm

Contact Closure

Use an RJ45 connector in the
CC1 socket on the control box
to operate via contact closure





SLQV

Warning lights
- LED’s to show operation of limit
switches and in switch.

Any contact closure input whilst the
mechanism is in motion will stop the
movement and all other contact closure
commands will be disabled for 1 second.

568A

568B

1

12V SUPPLY

12V SUPPLY - CURRENT LIMITED

W/G

W/O

2

12V LATCH

When 12V attached, device will go OUT. When

12V removed, device will go IN.

G

O

3

GROUND

GROUND

W/O

W/G

4

DEVICE LATCH

Momentary short to GROUND (pin 3), device will

go IN.

BL

BL

5

VIEWING ANGLE D

Momentary short to GROUND (pin 3), moves

arm out to viewing angle D.

W/BL

W/BL

N / A

6

VIEWING ANGLE F

Momentary short to GROUND (pin 3), moves

arm out to viewing angle F.

O

G

N / A

7

PRESET

Momentary short to GROUND (pin 3), moves

arm to recess position, head parallel.

W/BR

W/BR

N / A

8

DEVICE IN

Momentary short to GROUND (pin 3), makes

device go fully IN.

BR

BR

N / A

PIN

DESCRIPTION

ACTION

WIRE / CABLE

CONTACT CLOSURE

LED INDICATOR