Sheet6, Drawing view19, Drawing view20 – Future Automation EAD User Manual

Page 6: Detail view b (1.5 : 1), Future automation, Contact closure, Instruction sheet, Electric advance & drop

Advertising
background image

1

8

pins

There are a number of LEDs

which will light up when the

corresponding contact closure

connections are shorted together.

A red LED will light up when the

emergency stop link is removed.

B

DETAIL B

Contact Closure

Use an RJ45 connector in the

CC1 socket on the control box

to operate via contact closure.

Momentary short to ground

will make device go IN. CC1

Momentary short to ground

will make device go OUT. CC2

When shorted to ground,

stops device in current position. CC3

When shorted to ground, device will go OUT.

When short removed, device will go IN. CC4

Momentary short to ground will switch the

device between states of IN / OUT. CC5

When 12V is attached, device will go OUT.

When 12V is removed, device will go IN.

DEVICE IN

DEVICE OUT

DEVICE STOP

DEVICE IN LATCHED

GROUND

12V LATCH

12V SUPPLY CURRENT LIMITED

BR

W/BR

G

W/BL

BL

W/G

O

W/O

BR

W/BR

O

W/BL

BL

W/O

G

W/G

8

7

6

5

4

3

2

1

ACTION

DESCRIPTION

568

B

568

A

PIN

DEVICE TOGGLE

Sheet 6 of 8

ISSUE: 003

www.futureautomation.co.uk

FUTUREAUTOMATION

Instruction Sheet

EAD

Electric Advance & Drop

Advertising