Page 12 of 18 // email [email protected] tel: +44 (0) 1438 833577 fax: +44 (0) 1438 833565

PICH - Picture Lift Heavy Mechanism





SLQV

Contact Closure

- Use an RJ45 connector in the CCI
socket on the control box to operate
via contact closure

LED 1
LED 2
LED 3

LED 4
LED 5

CONTACT CLOSURE INPUT

NOTE:
Earlier versions of the control board
may not have these contact closure
LED indicators.

568A

568B

1

12V SUPPLY

12V SUPPLY - CURRENT LIMITED

W/G

W/O

2

12V LATCH

When 12V attached, device will go OUT. When

12V removed, device will go IN.

G

O

3

GROUND

GROUND

W/O

W/G

4

PIN 4 NOT USED

BL

BL

5

DEVICE LATCH

Short to GROUND (pin 3), device will go OUT,

remove short device will go IN.

W/BL

W/BL

LED 4

6

DEVICE STOP

Momentary short to GROUND (pin 3), stops

device in current position.

O

G

LED 3

7

DEVICE OUT

Momentary short to GROUND (pin 3), makes

device go OUT.

W/BR

W/BR

LED 2

8

DEVICE IN

Momentary short to GROUND (pin 3), makes

device go IN.

BR

BR

LED 1

PIN

DESCRIPTION

ACTION