3. INSTALLATION

Operation manual b40, chapter 3 -installation- page 3-3




The digital audio toolbox b40 can be remote-controlled by
means of parallel GPI contacts.

use :

remote-controlled changeover of presets

connector:

D-SUB 15pin, female


Pin assignments


Pin

Signal name

Logic

I/O

Functions

1

PRESET1

L

I

recall preset1

2

PRESET2

L

I

recall preset2

3

PRESET3

L

I

recall preset3

4

PRESET4

L

I

recall preset4

5

PRESET5

L

I

recall preset5

6

PRESET6

L

I

recall preset6

7

PRESET7

L

I

recall preset7

8

PRESET8

L

I

recall preset8

9

MUTE

L

I

Muting outputs

10 BYPASS

L

I bypass

on

11 not

used

12

Phase rev ch1/2

L

I

13

Phase rev ch3/4

L

I

14

Common pin

External voltage feed

15

+5V

O

Test power source

Ground on shield of the connector only!

Electrical specification:

GPI input

potential free by opto-coupler, low active

OFF:

+3.5…+30V between GPI input

and

pin14

ON:

less then 1.5V

min

50ms


Note: If using an external voltage feed it has to be connected to pin 14!
External Ground is switching the GPI on any of the inputs.
An internal voltage feed is available on pin 15. Ground is available from the
shield of the connector only! By using the internal voltage feed there is no
electrical isolation given anymore.

3.7

REMOTE
CONTROL

3.7.1

GPI REMOTE
CONTROL
(PARALLEL
REMOTE)

Pin1...13

Contact to
ext. Ground

Pin14

Ext. voltage
feed+3,5...30V

min. 50 ms

+1,5V

+3,5...30V