A 2 –Installation
Connector :
RJ 45 with status LEDs
Pin assignment of the connector :
Pin
Signal name
Functions
1
TX +
Ethernet send
2
TX -
Ethernet send
3
RX +
Ethernet receive
4
5
6
RX -
Ethernet receive
7
8
9
Electrical specifications:
100Mbit/s auto negotiation port
Application remarks :
This port allows the remote control of the d07 by TCP/IP over Ethernet.
Setting up the network configuration is described in B 6.
The LAN Controller of the d07 has a web server which offers a graphical user
interface (GUI). For proper operation you need IE7 or FireFox 2.0. There you
input the IP address of the d07 as an URL.
d07 control block diagram :