Receiver Left View





Connectors:

:

12VDC

: Power Supply Ground

RX1: Channel 1 Fiber Optic
RX2: Channel 2 Fiber Optic
RX3: Channel 3 Fiber Optic
RX4: Channel 4 Fiber Optic

LEDs Definition:

POW:

Power Supply. On if power input is in OK.

SYNC: Channel 4 Fiber link. Off if the fiber link is in OK.

2.4 Operate Instruction

1) Connect transmitter to monitor via DVI cable.

2) Turn on monitor and transmitter.

3) Press the button at transmitter until the STS LED stops flashing (accompanying a

beep), this indicates that the transmitter is reading EDID data from monitor .Then

release the button.

4) In about 30 seconds, the STS LED flashes again accompanying a beep, this

indicates the successful reading of EDID. If the STS LED flashes without beep, this

indicates the failure of reading EDID. Try to operate again and check DVI cable if

necessary.

5) After reading EDID data, connect transmitter DVI port to PC host DVI port.

2.5 Caution

Switch off all power supply before installation

Ensure fiber is properly aligned to the receiving connector

Do NOT stare at the fiber core