Protecting the speakers / operating safety, 3 preventing hearing damage, 4 protecting the speakers / operating safety – KLING & FREITAG K&F SONA 8 User Manual

Page 8

Advertising
background image

User's manual

K&F SONA 8

KLING & FREITAG GMBH © 2014

Version 1.1

Page 8 of 21

3.3

Preventing hearing damage

Caution

Avoid beeing too close to operating speakers. This equipment is capable of delivering sound
pressure levels in excess of 90 dB SPL, which may cause permanent hearing damage.

3.4

Protecting the Speakers / Operating Safety

In general, audio signals must not be overdriven. This may be caused by mixing consoles,
equalizers, effect equipment, etc. and should be indicated on this equipment. When a power
amplifier is overloaded at the output (clipping), then the amplifier should activate a clipping
warning signal. Power amplifiers can also be overloaded at the input circuit without the
amplifier signalling the clipping, i.e. when there is not sufficient headroom in the input
circuit. We, therefore, recommend turning up the power amplifiers all the way and adjusting
the level before the power amplifier in order to avoid overloading the input circuit. In any
case, the signal must be reduced as soon as it sounds unnaturally distorted.

Operations without CD 44 Controller:

To protect the speakers from being destroyed and to avoid fire hazard, they should
only be operated with professional power amplifiers with a maximum rated output
power of 500 W @ 8 Ohm.

If power amplifiers have power ratings lower than 250 W @ 8 Ohm, then it is
imperative that the amplifiers have clipping limiters. Alternately, you can also insert a
clipping limiter before the amplifier.

To protect the loudspeaker from mechanical damage when high SPL is required a
highpassfilter of 24dB/oct. at 60Hz has to be inserted into the signal chain.

Operations with CD 44 Controller:

For optimal performance and operating safety of the SONA 8 speakers we recommend
using the system controller K&F CD 44.

When operating the loudspeaker with amplifers without clipping limiter and nominal
amplifier power less than 100 W requires to set a Limit Reduction of 3dB for the K&F
CD 44 controller. You can find more detailed information about this option in the
K&F CD 44 hardware manual.

The destruction of speakers and the risk of fire as a result of a very rare power
amplifier or speaker defect may not be avoided by the controller in any case.

For damage caused by

overloading the speakers

using power amplifiers with other than the recommended maximum output power

we do not assume warranty and excludes liability for possible consequential damage.

The following signals may damage the speakers:

clipping power amplifiers

permanent high-level signals with high frequency and continuous noise from feedback.

permanently distorted high-level signals.

noises, which occur when the amplifier is on while equipment is being connected,
disconnected or switched on.

Do not install devices in any of the following places:

where the devices are permanently exposed to direct sunlight.

where the devices are exposed to high moisture or rain.

where the devices are exposed to strong vibrations and dust.

Advertising
This manual is related to the following products: