Pir-88m connections (continued), Page 6, Figure 3.5: control port pin-out – Oxmoor PIR-88M User Manual

Page 8: Use belden #9681 or equivalent, Control port connections, Pin function pin function, Description function

Advertising
background image

Page 6

PIR-88M CONNECTIONS (CONTINUED)

Figure 3.9: PA-422 Typical Connection Scheme

CONTROL PORT

PA-422 IN

CHASSIS

PA-422 OUT

+15 GND – 15

OXMOOR

MADE IN USA BY

OXMOOR CORPORATION

BIRMINGHAM, ALABAMA

SERIAL #

PA-422 IN

PA-422 OUT

PA-422 Controller

PA-422 OUT of Controller

PA-422 IN of PIR-88M

Use Belden #9681

or

Equivalent

Pin 37

Pin 1

Figure 3.7: PA-422 Serial Control Port View

Figure 3.4: Control Port View

CONTROL PORT CONNECTIONS

(Refer to Figures 3.4, 3.5 and 3.6)

The PIR-88M Infrared Modulator Matrix Control Port provides
connections for external programming and selections of eleven
presets. Also provides tally connections for all control
functions.

All control functions are operated by simple momentary
contact closures.

PA-422 SERIAL CONTROL PORT CONNECTIONS

(Refer to Figures 3.7, 3.8 and 3.9)

All PRM-8 functions can be controlled through the PA-422
serial control port. See Wiring detail below.

Figure 3.5: Control Port Pin-Out

1

Channel 1/Preset 1

2

Channel 2/Preset 2

3

Channel 3/Preset 3

4

Channel 4/Preset 4

5

Channel 5/Preset 5

6

Channel 6/Preset 6

7

Channel 7/Preset 7

8

Channel 8/Preset 8

9

Preset 9

10

Preset 10

11

Preset 11

12

Not Used

13

Program Enable

14

Not Used

15

Not Used

16

+15 VDC

17

Bias for Back-EMF

18

Common

19

Common

20

Channel 1/Preset 1 Tally

21

Channel 2/Preset 2 Tally

22

Channel 3/Preset 3 Tally

23

Channel 4/Preset 4 Tally

24

Channel 5/Preset 5 Tally

25

Channel 6/Preset 6 Tally

26

Channel 7/Preset 7 Tally

27

Channel 8/Preset 8 Tally

28

Preset 9 Tally

29

Preset 10 Tally

30

Preset 11 Tally

31

Program Tally

32

Not Used

33

Not Used

34

+15 VDC

35

Bias for back-EMF

36

Common

37

Common

Pin

Function

Pin

Function

Figure 3.8: PA-422 Serial Control Port Wiring

1

2

3

4

5

6

7

8

9

1

2

3

4

5

6

7

8

9

+

+

MALE

+

+

RxD

FEMALE

_

RxD

_

DSR

_

DSR

_

DTR

_

+

+

TxD

_

DRAIN (SHIELD) WIRE

DTR

_

+

+

TxD

_

Use Belden #9681 or equivalent.

PORT

PA-422 IN

PA-422 OUT

+15 GN

R

BY

ATION

ABAMA

CONTROL PORT

PA-422 IN

PA-422 OUT

Channel X

Used to program/select Presets

Preset X

Program Enable

Toggles between:

A. Preset Mode
B. Channel Select Mode
C. Preset Assign Mode
D. Review Mode

Channel X Tally

Provides open-collector closure to
common when control function is active

Preset X Tally

Provides open-collector closure to
common when control function is active

Program Enable Tally

Provides open-collector closure to
common when control function is active

Common

Logic Common

Bias for Back-EMF

Used with external power supply to
protect the open-collector outputs from
the back EMF of the relay coil.

+15 VDC

DC voltage to power Tally LEDs

Figure 3.6: Control Port Functions and Descriptions

Description

Function

Advertising