Configuration and settings, Mechanical dimensions (unit=mm), Pin assignment of network connections – Signamax 8-Port 10/100/1000 Compact Industrial Unmanaged Switch User Manual
Page 2

PIN
MDI(1000base-T)
MDI(10/100base-T)
1
TP1+
TX+
2
TP1-
TX-
3
TP2+
RX+
4
TP3+
5
TP3-
6
TP2-
RX-
7
TP4+
8
TP4-
4
5
7
8
065-7408GTB Front-panel view, Backboard rear view and Housing side
view
7
4
(including the optional mounting kit)
8
5
9
0
.6
1
03
.2
1
15
.2
2
7.
2
9
0
.6
Configuration and Settings
No settings or configuration parameters are necessary.
Mechanical dimensions (unit=mm)
P2
P1
Pin Assignment of Network
Connections
RJ-45
1
8
V+ V- V+ V- F.G.
P2 P1
7
8
5
6
3
4
1
2
RJ-45 8-wiring normal definition
Switch
PC(NIC)
45.4
Front-panel view
RJ-45 Plug Pin 1
Straight-Through Cable
Cable Wiring
3
3
6
6
1
1
2
2
4
4
5
5
7
7
8
8
RJ-45 8-wiring Cross-Over definition
Cross-Over Cable
RJ-45 Plug Pin 1
Cable Wiring
3
1
6
2
1
3
2
6
32.2
45.4
Backboard rear view
(Mount kit)
78.7
90.3
Housing side view