Troubleshooting guide 24 – United States Stove Company 5040 User Manual

Page 26

Advertising
background image

TROUBLESHOOTING GUIDE

24

HIGH LIMIT SWITCH KEEPS TRIPPING
Possible Causes:

Possible Remedies:

1. The convection blower is overheating and tripping the

internal temperature shutoff.

Clean any dust off the windings and fan blades. If oiling the

blower does not help, the blower may be bad

2. The stove is being left on the highest setting for exten-

ded periods of time.

The highest level setting is designated for use over short

periods of time. Burning the stove on the highest setting

for longer that 1-2 hours could lead to potential overheating

situations.

3. Fuel other than wood pellets is being burned in the stove.

United States Stove Company pellet stoves are designed

and tested to use wood pellets. Check for signs of fuel oth-

er than wood pellets. No other type of fuel have been ap-

proved for United States Stove Company pellet stoves. If

there are signs of other types of fuel being used, stop using

them immediately.

4. Power surge or

brown out situation.

A power surge, spike, or voltage drop could cause the high

limit switch to trip. Check to see if a surge protector is being

used on the stove. If not, recommend one to the consumer.

5. High limit switch is malfunctioning.

If the other items checked out ok, replace the high limit

switch.

DIGITAL CIRCUIT BOARD TIMING RATES

Heat Level Setting

BIG E

1 & 3

1.4 seconds

1

2 seconds

1 & 4

2.5 seconds

2

4 seconds

3

7 seconds

4

9 seconds

5

12 seconds

Total Cycle Time

14.5 seconds

SMOKE SMELL OR SOOT BUILD-UP

Because it is a wood-burning device, your appliance may emit a faint wood-burning odor. If this increases beyond normal or

is you notice an unusual soot buildup on walls or furniture, check your exhaust system carefully for leaks. All joints should be

properly sealed. Also, clean your stove following instructions in “

MAINTENANCE.” If problem persists, contact your dealer.