VENTING
INSTALLATION

Continued

Continued

• Complete familiarity with chimney con-

dition, height, size, clearance to combus-
tibles and other factors is essential.

CHIMNEYS

NOTICE: Consult the authority
having jurisdiction in your area
regarding masonry chimney vent-
ing applications.

NOTICE: A complete chimney
inspection by a qualified person
should be performed.

• Appliances using B-vent connectors to

vent into a masonry or factory-built
chimney should not exceed 1

1

/

2

feet in

length for every inch of connector diam-
eter (3" vent connector has a maximum
4

1

/

2

foot length; 5" connector has maxi-

mum 7

1

/

2

foot length).

• Oversized chimneys should be relined

with appropriate listed relining systems.

• Cleanout access may be required.

Figure 28 - Straight Installation into
Masonry Chimney

HIGH ALTITUDE
INSTALLATION

Your Sun Valley B-vent freestanding stove
and burner system has been AGA tested and
approved for elevations from 0-2000 feet and
CGA certified for elevations from 0-4500 feet.

When installing this stove and burner sys-
tem at an elevation above 2000 feet (in the
USA), you may need to decrease the input
rating by changing the existing burner ori-
fice to a smaller size. Reduce input 4% for
each 1000 feet above sea level. Check with
your local gas company for proper orifice
size identification and proper orifice for
your location.

When installing this fireplace at an eleva-
tion above 4500 feet (in Canada), check
with local authorities.

For assistance with any high altitude installa-
tion contact DESA International’s Technical
Service Department at 1-800-DESA-LOG
(1-800-337-2564).

NOTICE: Consult the authority
having jurisdiction in your area
regarding listed chimney liner
venting applications.

WARNING: Operation of im-

properly installed and maintained
venting system could result in
serious injury, property damage,
or loss of life.

RELINING SYSTEMS

• Suitability and approval of relining ma-

terials should be determined.

• Condition, size, height, and termina-

tion of the chimney to be relined must
be determined.

• No substitution of components should

be made.

• Joints and connectors should be made

according to manufacturer’s instructions.

Figure 29 - Typical Straight Installation