Hardware preparation and installation, 1 environmental and power requirements, 1 environmental requirements – Artesyn COMX-P1022 Installation and Use (July 2014) User Manual
Page 33: Table 2-1, Environmental requirements, Outline, Chapter 2

Chapter 2
COMX-P1022 COM Express Module Installation and Use (6806800M04C)
33
Hardware Preparation and Installation
2.1
Environmental and Power Requirements
2.1.1
Environmental Requirements
The following table lists the environmental requirements that the board must meet when
operated in your particular system configuration.
Operating temperatures refer to the temperature of the air circulating around the board and
not to the component temperature.
Product Damage
High humidity and condensation on surfaces cause short circuits.
Do not operate the system outside the specified environmental limits. Make sure the
product is completely dry and there is no moisture on any surface before applying power.
Table 2-1 Environmental Requirements
Requirement
Operating
Non-Operating
Temp Cycle Class
-40°C to 85°C:500 cycles
Temperature
0°C to 60°C
-40°C to 85°C
Humidity
10% to90% (non-condensing)
Vibration
0.01g2/Hz @ 5-500Hz (Random Vibration)
Shock
20G peak 11ms (half sine)
Altitude
-60 to 4000m ASL