3 power requirements, 2 unpacking and inspecting the module, Table 2-3 – Artesyn COMX-P1022 Installation and Use (July 2014) User Manual
Page 35: Board power supply current requirements, Hardware preparation and installation
Advertising

Hardware Preparation and Installation
COMX-P1022 COM Express Module Installation and Use (6806800M04C)
35
2.1.3
Power Requirements
2.2
Unpacking and Inspecting the Module
Table 2-3 Board Power Supply Current Requirements
0.75V
1.0V
1.2V
1.5V
1.8V
2.5V
3.3V
CPU(P1022)
6000
1000
100
200
DDR3
600
4400
USB PHY(3315)
55
USB HUB(2514)
415
GE PHY BCM5482
260
88
DS90C385
493
TFP410PAP
250
74LVCH32244A x2
120
Total 23.17W
0.45W 6W
3.12W 8.1W
0.5W
5W
Damage of Circuits
Electrostatic discharge and incorrect installation and removal of the product can damage
circuits or shorten its life.
Before touching the product make sure that you are working in an ESD-safe environment or
wear an ESD wrist strap or ESD shoes. Hold the product by its edges and do not touch any
components or circuits.
Advertising