Hardware preparation and installation, 1 environmental and power requirements, 1 environmental requirements – Artesyn NITX-300-ET-DVI Installation and Use (August 2014) User Manual
Page 21: Table 2-1, Environmental requirements of nitx-300-et-dvi, Outline, Chapter 2

Chapter 2
NITX-300-ET-DVI Installation and Use (6806800N97B)
21
Hardware Preparation and Installation
2.1
Environmental and Power Requirements
2.1.1
Environmental Requirements
The following tables list the environmental requirements that NITX-300-ET-DVI board must
meet when operated in your particular system configuration.
Operating temperatures refer to the temperature of the air circulating around the board and
not to the component temperature.
Product Damage
High humidity and condensation on surfaces cause short circuits.
Do not operate the system outside the specified environmental limits. Make sure the
product is completely dry and there is no moisture on any surface before applying power.
Table 2-1 Environmental Requirements of NITX-300-ET-DVI
Requirement
Operating
Non-Operating
Cooling Method
Fanless
Temp Cycle Class
-40-+85C:500cyc
Temperature
-40 °C to +85 °C
-40 °C to +85 °C
Humidity
10-90% (non-condensing)
Vibration
.01 g^2/Hz @ 5-500Hz
Shock
20g 11ms sine or saw
Altitude
-60 - 4000 m ASL