1 2 installation, Fireplace placement requirements – Avalon Firestyles 564 SS Gas Installation User Manual

Page 12

Advertising
background image

1 2

Installation

(for qualified installers only)

Travis Industries

4 0 7 0 6 2 0

100-01188_000

Fireplace Placement Requirements

•

The fireplace requires a 1/2" clearance from the angled sides and back of the fireplace to the framing
members. No material (insulation, framing, etc.) may be placed into this area.

•

Fireplace must be installed on a level surface capable of supporting the fireplace and vent

•

Fireplace must be placed directly on wood or non-combustible surface (not on linoleum or carpet)

•

This heater may be placed in a bedroom. Please be aware of the large amount of heat this appliance
produces when determining a location.

Clearances

•

When installed, walls in front of the fireplace must be a minimum 1" to the side of the fireplace.

•

Due to the high temperature, the heater should be located out of traffic and away from furniture and
draperies.

•

Fireplace must be placed so the vents below and above the glass do not become blocked.

Raised Fireplaces

•

The fireplace (and hearth, if desired) may be placed on a platform designed to support the fireplace
(155 Lbs.) and vent.