Installation, Top vent configuration with vertical termination, For qualified installers only) – Avalon Firestyles 564 SS Gas Installation User Manual

Page 31

Advertising
background image

Installation

(for qualified installers only)

3 1

© Travis Industries

4 0 7 0 6 2 0

100-01188_000

Top Vent Configuration with Vertical Termination

•

The termination must fall
within the shaded area shown
in the chart. Use the indicated
restrictor and diffuser
positions.

•

Up to four elbows (45

°

or 90

°

)

may be used.

•

Only one horizontal elbow
may be used.

•

May use 8" or 6-5/8" diameter
vent (see page for 22 details).

5 feet

0 feet

0 feet

5 feet

0 feet

20 feet

20 feet

5 feet

10 feet

5 feet

10 feet

0 feet

15 feet

20' (max)

10 feet

15 feet

15 feet

20' (max)

10 feet

15 feet

40' (max)

Exhaust Restrictor # 4

Intake Restrictor # 2
Diffuser Position # 2

25 feet

30 feet

35 feet

40' (max)

25 feet

30 feet

35 feet

This is considered a horizontal

elbow (it does not matter

whether it turns right or left).

It may be a 90° or 45° elbow.

This is considered a

vertical elbow

Horizontal length is calculated by adding

both lengths of horizontal run

(Horizontal Length = H1 + H2).

H1

H2