Installation – Avalon Firestyles 564 SS Gas Installation User Manual

Page 27

Advertising
background image

Installation

(for qualified installers only)

2 7

© Travis Industries

4 0 7 0 6 2 0

100-01188_000

Rear Vent Configuration with Horizontal Termination (no vertical rise)

•

The termination must fall within the shaded area shown in the chart. Use the indicated restrictor and
diffuser positions.

Optional 45° Elbow

Termination

See the charts below to
determine maximum vent

3 feet

0 feet

0 feet

4' (max)

• Exhaust Restrictor # 0 (stock)
• Intake Restrictor # 1 (stock)
• Diffuser Position # 1 (stock)

Vent with No 45° Elbow

3 feet

0 feet

0 feet

2' (max)

Vent with 1 45° Elbow

• Min. 4" Horizontal Section
• Max. 24" Horizontal Section(s)

• Min. 4" Horizontal Section
• Max.48" Horizontal Section(s)

• Exhaust Restrictor # 0 (stock)
• Intake Restrictor # 1 (stock)
• Diffuser Position # 1 (stock)