Operation, Fault" light, Power outages – Avalon Firestyles Astoria 2001 to 2002 User Manual
Page 25

Operation
2 3
Travis Industries
4 0 1 1 0 0 9
9 3 5 0 8 1 2 6
"FAULT" Light
This light comes on when an error occurs:
•
The stove runs out of pellets
•
During initial start-up (for a split second) or for improper electrical frequency
•
A start-up sequence that does not result in the heater coming up to temperature
HEAT OUTPUT
AUTO
OFF
MANUAL
MANUAL
START
FAULT
W
O
L
H
E D
M
I
G
H
W
O
L
H
E D
M
I
G
H
FAN
To reset the fault light, turn the mode switch to off and re-start the stove.
Power Outages
If a sustained power outage occurs while in "Manual", the stove will go to a "cool down" mode to
vacate smoke once power returns. If the power outage was short, the heater will go to the start-up
sequence. If in "Auto", the stove will re-start (if the room is cool).
!
Because this stove relies upon a blower to evacuate the smoke, some smoke may enter
the home during a power outage. To keep to a minimum, leave the door closed.