Maintenance, Yearly maintenance (or every two tons) - continued – Avalon Firestyles Astoria 2001 to 2002 User Manual

Page 34

Advertising
background image

3 2

Maintenance

Travis Industries

4 0 1 1 0 0 9

9 3 5 0 8 1 2 6

Yearly Maintenance (or every two tons) - Continued

Check for Air Leaks Around the Door, Glass, and Ashpan

!

Air leaks into the firebox will decrease the stove's performance greatly, leading to excessive
sooting, inefficient burning, and perhaps a malfunction.

•

Test the door seal by shutting the door on a dollar bill in various locations. If the bill can be easily
slid out, air may be leaking around the door seal – inspect the door gasket and door catch
carefully.

•

Inspect the door gasket to make sure it is fully attached. Use stove gasket cement to re-attach if
necessary. If the door gasket is worn or flattened, replace.

•

Check the door to make sure it latches correctly. Slight adjustments can be made to the door
catch if necessary (do not over-tighten this catch, an over-tightened catch will damage the door).
The latch should engage with a slight amount of resistance, yet not be difficult to engage.

•

If the glass is cracked, replace. The glass is held in place by glass clips that are underneath the
airwash brackets. See the illustration below for details.

•

Remove the ashpan and inspect the gasket around the perimeter of the ashpan. Re-attach, or
replace the gasket if necessary.

Door

Gasket

Airwash Bracket

Door
Frame

Door

Glass (with

channel gasket)

Door

Gasket

Glass Clips

Airwash Brackets

Glass Clip

5/16"

Nutdriver

Attachment

Nuts

Airwash Spacers

Airwash

Spacer

Replacement Parts

Blower, Combustion

93005535

Igniter

99300149

Blower, Convection

98900755A

Knob, Air Control Cover

91001606

Outside Air Kit

99200136