Installation, Clearances - straight installation, Clearances - corner installation – Avalon Firestyles Astoria 2001 to 2002 User Manual

Page 9

Advertising
background image

Installation

7

Travis Industries

4 0 1 1 0 0 9

9 3 5 0 8 1 2 6

Clearances - Straight Installation

6” Minimum

3” Minimum

9” Minimum

3”

Minimum

Through the Wall Installations

Interior Vertical Vents

Floor Protection

6” Minimum

2”

Minimum

9” Minimum

“Tee”

Clearances - Corner Installation

6” Minimum

Through the

Wall Vents

3” Minimum

45° Elbow

45°

3” Minimum

Interior Vertical

Vents

3”

Minimum

6” Minimum

2”

Minimum

Floor Protection

“Tee”

3” Minimum

3”

Minimum

Note:

If interior vertical pellet vent is used, the clearance to the backwall is determined by the
upward-turning elbow or "Tee". It will vary in depth depending on the brand of pellet vent
used (it is approximately 5"). Before placing the heater, connect the elbow or "Tee" and
measure off the 3" clearance.