INSTALLATION

Continued

CONNECTING FIREPLACE TO GAS
SUPPLY

Installation Items Needed

• 5/16" hex socket wrench or nut-driver

• Phillips screwdriver

• sealant (resistant to propane/LP gas, not provided)

1. Remove fireplace screen. Remove two screws

that hold fireplace screen in place for shipping.

These screws are located near top of screen.

Discard screws. Lift fireplace screen up and

pull out to remove.

2. Remove screws that attach log base assembly

to fireplace (see Figure 19). Carefully lift up

log base assembly and remove from fireplace

(see Figure 19).

Note:

If adding the G8005 series brick liner acces-

sory, install it now. Follow instructions in G8005

accessory kit.

3. Route gas line (provided by installer) from

equipment shutoff valve to fireplace. Route

flexible gas supply line through one of the

access holes.

4. Attach the flexible gas line to gas supply (see

Figure 20). Check tightness of flexible gas

line attached to gas regulator of fireplace (see

Figure 20).

5. Check all gas connections for leaks. See

Checking Gas Connections, page 15.

6. Replace log base assembly back into fireplace.

Feed flexible gas line into fireplace base area

while replacing log base assembly. Make sure

the entire flexible gas line is in fireplace base

area. Reattach log base assembly to fireplace

with screws removed in step 2.

CAUTION: Do not pick up

log base assembly by burner.

This could damage burner. Only

handle base by grates.

NOTICE: Most building codes

do not permit concealed gas

connections. A flexible gas line

is provided to allow accessibility

from the fireplace (see Figure 20).

The flexible gas supply line con-

nection to the equipment shutoff

valve should be accessible.

Figure 19 - Removing Log Base

Assembly From Fireplace

Figure 20 - Attaching Flexible Gas Lines

Together

Flexible Gas Line
from Fireplace Gas
Regulator

To Fireplace Gas
Regulator

Equipment Shutoff
Valve Provided by
Installer

Propane/LP
To External
Regulator

Natural Gas
To Gas Meter

CHECKING GAS CONNECTIONS

WARNING: Test all gas piping

and connections, internal and

external to unit, for leaks after

installing or servicing. Correct

all leaks at once.

WARNING: Never use an

open flame to check for a leak.

Apply a noncorrosive leak detec-

tion fluid to all joints. Bubbles

forming show a leak. Correct all

leaks at once.