OBSERVED PROBLEM

Moisture/condensation noticed

on windows

Heater produces a whistling noise

when burners are lit

White powder residue forming

within burner box or on adjacent

walls or furniture

Remote does not function

Yellow flame in front burner dur-

ing burner combustion

Fireplace produces a clicking/

ticking noise just after burner is

lit or shut off

Dark residue on logs inside of

their fireplace Note: After remov-

ing all causes of residue deposits,

completely clean fireplace and

appliance off residue before reus-

ing appliance

REMEDY

1. Refer to Air for Combustion

and Ventilation requirements

(page 5)

1. Turn control knob to LO position

and let warm up for a minute

2. Operate burners until air is

removed from line. Have gas

line checked by local natural

or propane/LP gas company

3. Observe minimum installation

clearances (see page 9)

4. Clean burners (see Cleaning

and Maintenance, page 21) or

replace burner orifice(s)

1. Turn heater off when using

furniture polish, wax, carpet

cleaners, or similar products

1. Replace 9-volt batteries in

receiver and remote control

1. Check burner(s) for dirt and

debris. If found, clean burner(s)

(see Cleaning and Mainte-

nance, page 21)

2. Replace gas regulator

1. This is normal with most heat-

ers. If noise is excessive, contact

qualified service person

1. Properly locate logs (see In-

stalling Logs, page 16)

2. Eliminate source of drafts

around heater

3. Clean out air holes at burner

inlet. Periodically repeat as

needed

4. Remove blockage

POSSIBLE CAUSE

1. Not enough combustion/ven-

tilation air

1. Turning control knob to HI po-

sition when burners are cold

2. Air in gas line

3. Air passageways on heater

blocked

4. Dirty or partially clogged

burner orifice(s)

1. When heated, vapors from

furniture polish, wax, carpet

cleaners, etc. may turn into

white powder residue

1. Battery is not installed. Bat-

tery power is low

1. Not enough air

2. Gas regulator defective

1. Metal expanding while heating

or contracting while cooling

1. Improper log placement

2. Drafts or other air currents

affecting flame pattern

3. Air holes at burner inlet

blocked

4. Burner flame holes blocked

TROUBLEShOOTING