Product identification, Safety information, Local codes – Desa VSGF33NRC User Manual

Page 4

Advertising
background image

www.desatech.com

119304-01A

4

SAFETy INFORMATION

Continued

6. Do not add extra logs or ornaments such as

pine cones, vermiculite, or rock wool. Using

these added items can cause sooting. Do not

add lava rock around base. Rock and debris

could fall into the control area of fireplace.

7. To prevent the creation of soot, follow the

instructions in Cleaning and Maintenance,

page 21.

8. Before using furniture polish, wax, carpet

cleaner, or similar products, turn heater off.

If heated, the vapors from these products may

create a white powder residue within burner

box or on adjacent walls or furniture.

9. This fireplace needs fresh air ventilation to run

properly. This fireplace has an Oxygen Deple-

tion Sensing (ODS) safety shutoff system. The

ODS shuts down the fireplace if enough fresh

air is not available. See Air for Combustion and

Ventilation, page 5. If fireplace keeps shutting

off, see Troubleshooting, page 23.

10. Do not run fireplace

• where flammable liquids or vapors are used

or stored

• under dusty conditions

11. Do not use this fireplace to cook food or burn

paper or other objects.

12. Do not use fireplace if any part has been exposed

to or under water. Immediately call a qualified

service technician to inspect the fireplace and to

replace any part of the control system and any

gas control which has been under water.

13. Do not operate fireplace if any log is broken.

Do not operate fireplace if a log is chipped

(dime-sized or larger).

14. Turn fireplace off and let cool before servicing.

Only a qualified service person should service

and repair fireplace.

15. Operating fireplace above elevations of 4,500

feet could cause pilot outage.

16. To prevent performance problems in

propane/LP units, do not use propane/LP

fuel tanks of less than 100 lbs. capacity

(propane/LP units only).

17. Provide adequate clearances around air

openings.

PRODUCT

IDENTIFICATION

Figure 1 - Log Base Assembly

Optional
Blower
Assembly
(Not
Included)

Top Louver
Assembly

Fireplace
Hood

Bottom
Louver
Assembly

Screen
Assembly

Top Outer Casing

Firebox
Support

Figure 2 - Fireplace

LOCAL CODES

Install and use fireplace with care. Follow all local

codes. In the absence of local codes, use the lat-

est edition of The National Fuel Gas Code ANSI

Z223.1/NFPA 54*.

*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

Note:

Where listed vented decorative logs are

required, thermostat operation is not permitted.

Optional
Remote
Control

Log Set

Base
Assembly

Front
Burner

Rear
Burner