Axel AX4000 User's Manual User Manual

Page 33

Advertising
background image

Setting-Up the Office Server in Interactive Mode


AXEL Office Server

27

Note: to use the axttyd Unix daemon, set the service as follow:

- ID string: y
- Auto Connection: yes
- time-out: 0

b - Server Tty

Select [Serial Lines]

[Line X][Network Service] and enter the following

parameters:

- Service Mode: enter the keyword ‘server',
- Service Type: enter the keyword ‘tty',
- TCP Port: numeric value associated with this Office Server serial line.
- TCP Keepalive Timeout: the keepalive mechanism allows the Office

Server to regularly check its TCP/IP connection status.

IMPORTANT: please, read appendix A.8 to set-up the keepalive

mechanism and to understand consequences of the keepalive use
(especially for routers).

2.5.4 - Any Devices on Windows

a) Presentation

The Office Server serial port can be controlled as standard operating system
local COM ports. Any software can use standard O.S. commands to control
these "virtual COMs":

- to send or receive data,
- to set serial line parameters (baud rate, parity, etc),
- to set serial output signals (DTR and RTS),
- to get serial input signals (DSR, CTS and CD).

IMPORTANT: the difference between virtual COMs and real COMs is the
reaction time. Due to the network latency, delay can be observed between a
serial port operating system operation and its achievement at the Office Server
serial port level. And if software uses short timer, error processing could be
reported with the virtual port.

This virtual COM control is based on a telnet protocol extension: RFC 2217
(RFCs can be consulted at ftp://ftp.merit.edu/documents/rfc/).

Advertising