Inspecting burner, Warning, Notice – Desa CGP18C User Manual

Page 20

Advertising
background image

20

101805

If pilot flame pattern is incorrect, as shown in Figure 19

• turn heater off (see To Turn Off Gas to Appliance, page 19)
• see Troubleshooting, pages 21 through 24

BURNER FLAME PATTERN

Figure 20 shows a correct burner flame pattern. Figure 21 shows an incorrect
burner flame pattern. The incorrect burner flame pattern shows yellow tipping of
the flame. It also shows the flame higher than 1/2 the heat shield height.

INSPECTING

BURNER

Continued

WARNING ICON

G 001

WARNING

If yellow tipping occurs, your heater could produce increased
levels of carbon monoxide. If burner flame pattern shows yellow
tipping, follow instructions at bottom of this page.

NOTICE

Do not mistake orange flames with yellow tipping. Dirt or other fine
particles enter the heater and burn causing brief patches of orange
flame.

If burner flame pattern is incorrect, as shown in Figure 21

• turn heater off (see To Turn Off Gas to Appliance, page 19)
• see Troubleshooting, pages 21 through 24

Figure 20- Correct Burner Flame Pattern

Figure 21 - Incorrect Burner Flame Pattern

CORRECT FLAME PATTERN

AT HIGH POSITION

1/2 HEAT SHIELD
OR GLASS HEIGHT

1/2 HEAT SHIELD
OR GLASS HEIGHT

INCORRECT FLAME PATTERN

AT HIGH POSITION

Yellow
Tipping

Advertising