Air for combustion and ventilation – Desa CGP18C User Manual

Page 8

Advertising
background image

8

101805

Outlet
Air

Ventilated
Attic

Outlet
Air

Inlet
Air

Inlet Air

Ventilated

Crawl Space

To

Crawl

Space

To Attic

Figure 3 - Ventilation Air from Outdoors

AIR FOR

COMBUSTION

AND

VENTILATION

Continued

Ventilation Air From Outdoors

Provide extra fresh air by using ventilation grills or ducts. You must provide two
permanent openings: one within 12" of the ceiling and one within 12" of the floor.
Connect these items directly to the outdoors or spaces open to the outdoors. These
spaces include attics and crawl spaces. Follow the National Fuel Gas Code NFPA
54/ANSI Z223.1, Section 5.3, Air for Combustion and Ventilation
for required size
of ventilation grills or ducts.

IMPORTANT:

Do not provide openings for inlet or outlet air into attic if attic has

a thermostat-controlled power vent. Heated air entering the attic will activate the
power vent.