Trouble- shooting – Desa CGP18C User Manual

Page 23

Advertising
background image

23

101805

TROUBLE-

SHOOTING

Continued

OBSERVED
PROBLEM

Burner does not light
after ODS/pilot is lit
(continued from
page 22)

Delayed ignition of
burner

Burner backfiring
during combustion

Yellow flame during
burner combustion

Slight smoke or odor
during initial operation

Heater produces a
whistling noise when
burner is lit

POSSIBLE
CAUSE

2. Burner orifice diameter

is too small

3. Inlet gas pressure is

too low

1. Manifold pressure is

too low

2. Burner orifice is

clogged

1. Burner orifice is

clogged or damaged

2. Inlet gas pressure is

too low

3. Burner damaged
4. Gas regulator defective

1. Not enough air

2. Inlet gas pressure is

too low

3. Gas regulator defective

1. Residues from manu-

facturing processes

1. Turning control knob

to HIGH position
when burner is cold

2. Air in gas line

3. Air passageways on

heater blocked

4. Dirty or partially

clogged burner orifice

Continued

REMEDY

2. Replace burner orifice

3. Contact local propane/

LP gas company

1. Contact local propane/

LP gas company

2. Clean burner (see

Cleaning and Mainte-
nance
, page 21) or
replace burner orifice

1. Clean burner (see

Cleaning and Mainte-
nance
, page 21) or
replace burner orifice

2. Contact local propane/

LP gas company

3. Replace burner
4. Replace gas regulator

1. Check burner for dirt

and debris. If found,
clean burner (see
Cleaning and Mainte-
nance
, page 21)

2. Contact local propane/

LP gas company

3. Replace gas regulator

1. Problem will stop after a

few hours of operation

1. Turn control knob to

LOW position and let
warm up for a minute

2. Operate burner until air

is removed from line.
Have gas line checked
by local propane/LP gas
company

3. Observe minimum

installation clearances
(see Figure 4, page 10)

4. Clean burner (see

Cleaning and Mainte-
nance
, page 21) or
replace burner orifice

Advertising