Installation – Desa WMP20A User Manual

Page 11

Advertising
background image

www.desatech.com

119344-01B

11

Figure 12 - Installing Bottom Mounting

Screws

Side View

Front View

Wall

Spacer

Heater

Installing Bottom Mounting Screws
1. Locate two bottom mounting holes. These

holes are near bottom on back panel of
heater (see Figure 12).

2. Mark screw locations on wall.
3. Remove heater from mounting bracket.
4. If installing bottom mounting screws into

hollow or solid wall, install wall anchors.
Follow steps 1 through 4 under Attaching
To Wall Anchor Method
, page 10.

If installing bottom mounting screw into
wall stud, drill holes at marked locations
using 9/64" drill bit.

5. Replace heater onto mounting bracket.
6. Place spacers between bottom mounting

holes and wall anchor or drilled hole.

7. Hold spacer in place with one hand. With

other hand, insert mounting screw through
bottom mounting hole and spacer. Place
tip of screw in opening of wall anchor or
drilled hole.

8. Tighten both screws until heater is firmly

secured to wall. Do not over tighten.

Note: Do not replace front panel at this
time. Replace front panel after making
gas connections and checking for leaks
(see pages 12 through 14).

INsTAllATIoN

Continued

MOUNTING HEATER TO FLOOR
WITH OPTIONAL FLOOR KIT

Mounting Base Feet to Heater
1. Lay heater cabinet on its back on a table

with the heater bottom overhanging the
table edge.

2. Align holes in base foot with mounting holes

on bottom of cabinet (see Figure 13).

3. Secure base foot to heater using sheet

metal screws.

4. Repeat for other side.

Figure 13 - Installing Base Feet

Sheet Metal Screw

Wood
Screw

Base Foot

Mounting Base Feet to Floor
1. Remove front panel (see Removing Front

Panel of Heater, page 9).

2. Position heater with base feet in desired

location. Mark holes for drilling. Remove
heater with base.

3. For carpeted floors, make a small cut with

a sharp knife at marked locations prior to
drilling. If mounting base to a wood floor,
drill 1/8" diameter hole, 3/4" deep. (Do not
use anchors in wood floors).

If mounting base to a concrete floor, drill
with 1/4" diameter concrete drill bit, 1

3

/

8

"

into floor. Insert anchors completely into
holes.

4. Reposition heater with base feet over

holes. Secure base to floor with wood
screws. See Figure 13.

Advertising