3. Check all joints from gas meter for natural

gas (see Figure 17) or propane/LP supply
tank for propane/LP gas, to equipment
shutoff valve (see Figure 18). Apply a
noncorrosive leak detection fluid to all
joints. Bubbles forming show a leak.

4. Correct all leaks at once.

PRESSURE TESTING HEATER GAS
CONNECTIONS
1. Open equipment shutoff valve (see Figure

16, page 13).

2. For natural gas open main gas valve

located on or near gas meter. For pro-
pane/LP gas open propane/LP supply
tank valve.

3. Make sure control knob of heater is in the

OFF position.

4. Check all joints from equipment shutoff

valve to thermostat gas valve (see Figure
17 or 18). Apply a noncorrosive leak de-
tection fluid to all joints. Bubbles forming
show a leak.

5. Correct all leaks at once.
6. Light heater (see Operating Heater, start-

ing on page 15). Check all other internal
joints for leaks.

7. Turn off heater (see To Turn Off Gas to

Appliance, page 16).

8. Replace front panel.

Figure 18 - Checking Gas Joints for

Propane/LP Gas

Equipment Shutoff Valve

Propane/LP
Supply Tank

Thermostat Gas Valve

Figure 17 - Checking Gas Joints for

Natural Gas

Equipment Shutoff Valve

Gas
Meter

Thermostat Gas Valve