Inspecting heater – Desa WMP20A User Manual

Page 17

Advertising
background image

www.desatech.com

119344-01B

17

BURNER FLAME PATTERN

WARNING: If yellow tipping

occurs, your heater could pro-

duce increased levels of carbon

monoxide.

NOTICE: Do not mistake orange

flames with yellow tipping. Dirt

or other fine particles enter the

heater and burn causing brief

patches of orange flame.

Figure 24 shows a correct burner flame pat-
tern. Figure 25 shows an incorrect burner
flame pattern. The incorrect burner flame
pattern shows yellow tipping of the flame.
It also shows the flame higher than 1/2 the
glass panel height.
If burner flame pattern is incorrect, as shown
in Figure 25
• turn heater off (see To Turn Off Gas To

Appliance, page 16)

• see Troubleshooting, page 19

INsPeCTING HeATeR

Check pilot flame pattern and burner flame
pattern often.

PILOT FLAME PATTERN

Figure 22 shows a correct pilot flame pattern.
Figure 23 shows an incorrect pilot flame pat-
tern. The incorrect pilot flame is not touching
the thermocouple. This will cause the thermo-
couple to cool. When the thermocouple cools,
the heater will shut down.
If pilot flame pattern is incorrect, as shown
in Figure 23
• turn heater off (see To Turn Off Gas to Ap-

pliance, page 16)

• see Troubleshooting, page 19
Note: The pilot flame on natural gas units will
have a slight curve, but flame should be blue
and have no yellow or orange color.

Figure 23 - Incorrect Pilot Flame Pattern

Figure 22 - Correct Pilot Flame Pattern

Thermocouple

Pilot Burner

Pilot
Burner

Thermocouple

Blue Flame

Yellow Flame

Figure 24 - Correct Burner Flame Pattern

Yellow
Tipping

Figure 25 - Incorrect Burner Flame

Pattern

1

/



Glass

Height

1

/



Glass

Height

Blue
Flame

Advertising