Terminal configuration

KL6071

7


3.3 Control und Status Byte

Control byte during process data exchange

The control byte is transmitted from the controller to the terminal. It can be
used

during process data exchange (REG = 0

bin

) or

in register mode (REG = 1

bin

).

Bit

7

6

5

4

3

2

1

0

Name

REG=0

0

0

A4

A3

A2

A1

A0


Key

Bit

Name

Comment

7

REG

0 for Process data mode

6

0

reserved

5

0

reserved

4-0

A4-A0

Offset from where reading or writing is done.
The offset is calculated as follows:
(A4…A0) x 5



Status byte during process data exchange

The status byte is transferred from the terminal to the control system. It
acknowledges the bits of the control byte.

Bit

7

6

5

4

3

2

1

0

Name

REG=0

0

CS_ST

A4

A3

A2

A1

A0


Key

Bit

Name

Comment

7

REG

0 for Process data mode

6

0

reserved

5

CS_ST

State of the CS Input

4-0

A4-0

Address bits 0 to 4