Operation

EP1908-0002

31

4.5.3.1

EP1908-0002 configuration for light barriers, light grids, light curtains, etc.

The EP1908-0002 also supports direct connection of contact-free protective devices with two self-testing
outputs such as light barriers, light grids, light curtains, laser scanners, etc.

CAUTION

Sensors with self-testing outputs

Only sensors with self-testing outputs and a maximum sensor self-test duration of
350 µs may be connected to the EP1908-0002.


Parameter
To connect these sensors please set the following parameters for the EP1908-0002 in the TwinCAT
System Manager:

Connect the two sensor signals either to channels 1, 2 & 3 and 4, 5 & 6 or channels 7 & 8 and
activate asynchronous repetition OSSD or any pulse repetition for the two inputs used under
parameter Logic for channel x and y. The difference between these settings is that with any pulse
repetition
simultaneous tests of the OSSD signals up to 350 µs are allowed.

For the two inputs used set the sensor test for the EL1908-0002 to false.

4.5.3.2

EP1908-0002 configuration for safety switching mats

The EP1908-0002 also supports direct connection of safety mats that operate based on the cross-circuit
principle.

Parameter
To connect these safety mats please set the following parameters for the EP1908-0002 in the TwinCAT
System Manager:

Connect the two sensor signals either to channels 1, 2 & 3 and 4, 5 & 6 or channels 7 & 8 and
activate the entry short cut channel x/y is no module fault for the two inputs used under
parameter Logic for channel x and y.