Step 5: amplifier sizing – BECKHOFF AL2000 Application User Manual

Page 31

Advertising
background image

Eiserstraße 5 / D-33415 Verl / Telefon 05246/963-0 / Telefax 05246/963-149

31

Step 5: Amplifier sizing

For most servocontrollers the duration of the peakcurrent is limited from 0.25 to several seconds. If the current
exceeds the continous current during a period, longer than this specified time, the required continous current
must be raised to this higher level. So check whether in long periods the required current is over the continuous
current. Choose a servocontroller which can deliver the required I

cont

and I

peak

.

Here, from the specified K

rms

and the calculated F

rms

we obtain

The maximum force during the cycle is 630N, so the servo-amplifier has to generate a maximum current

Since the periods of I>I

cont

are no longer than 5 seconds the AX2006 is fullfilling the requirements.

For braking heavy loads from high speeds (for example 100 kg at 4 m/s) the motor feeds back the electrical
power into the servo-amplifier. Most of it is dissipated in a braking resistor. Of course this resistor should be of
sufficient power, especially when such situations occur frequently (for instance in short repeated moves).

Advertising