Installation 2 – Belshaw Adamatic TG50 Thermoglaze User Manual

Page 8

Advertising
background image

Belshaw Bros., Inc.

• www.belshaw.com • Phone 206-322-5474 • Fax 206-322-5425

2 MN-1720

Thermoglaze

50

Installation 2

WARNING

To avoid electrocuting yourself or damaging

the Thermoglaze, never allow water, steam,

cleaning solution, or other liquid to enter the

electrical panels or connections

Electrical:

Model Dimensions Power

Requirements

TG50

88"L x 40W x

63"H

See data tag


Make sure that the power requirements of the
Thermoglaze, shown on the data plate, match
your power source.
Only plug in to power source that matches the
required voltage and current for the
Thermoglaze. (The Thermoglaze unit TG50
comes standard with a Hubbel 360P6W plug that
needs a 360C6W socket or equivalent for
electrical current.
Thermoglaze must be electrically grounded and
connected in compliance with the National
Electrical Code, ANSI-NFPA 70, and applicable
municipal building codes.
Do not apply electrical power to the system until
the assembly has been completed. See Section 4
for the assembly of the Thermoglaze.

Venting:

Local codes prevail. The authorities having
jurisdiction are stated in NFPA 96-1994
regarding requirements for the Thermoglaze.

Building Layouts:

Specification sheets and AutoCAD drawings for
use in developing architectural drawings can be
provided by request. Please call your Belshaw
Bros., Inc. representative for help in defining
your requirements.