Freestanding toilet, Fault diagnostic – Blu Bathworks LF1062 User Manual

Page 10

Advertising
background image

2014-01

1 866 907 0122 blubathworks.com

®

9

w h e r e w a t e r m e e t s m o d e r n

®

®

188 Smithe Street, Vancouver, BC V6B 6A9 Canada | T 1.604.299.0122 | TF 1.866.907.0122 | F 1.604.299.0125 | blubathworks.com

freestanding toilet

fault diagnostic

LF1062 | LF1269 | LF8004

Problem/Symptom

Cause

Action/cure




Fill valve turns on/off without
toilet being flushed

Flush valve seal gasket is dirty

Inspect and clean flush valve seal gasket

Fill valve continuously running

Dirty fill valve seal

Shut off water supply. Open fill valve cap
and clean valve seal.

Poor flush

Water supply is not fully open

Open water supply valve

Toilet not flushing

Water supply vavle is closed

Open water supply valve

Push button is stuck

Tank lid is misaligned

Align the tank lid

Water supply pressure is too low

The minimum required supply pressure
is 20 psi. Consult your plumber.

Trapway is obstructed

Unclog trapway

Venting is obstructed

Clean venting pipes

Flush valve seal gasket is dirty

Inspect and clean flush valve seal gasket

1.

2.

3.

4.

5.

a)

a)

b)

a)

b)

c)

d)

a)

a)

Advertising