Thermostatic cartridge change and cleaning

Through years of use, impurities and lime scale could restrict flow of water through the filters
of the cartridge.

To clean the filters:
•

Shut off the water supply to both inlets

•

Remove the lever (1), remove the grub screw (2) with 2.5mm /

1

/

16

” Alan key, remove the temperature

control knob (3) and temperature stop ring (4).

•

Remove the chrome ring (5) and the screw (6) with 3mm /

1

/

8

” Alan key.

•

Use the extension of the cartridge (7) like a device to unscrew the thermostatic cartridge (8). Unscrew
the cartridge using 30mm / 1

1

/

6

” spanner, wash filters (9) under running water or leave to soak in

vinegar or de-scalding agent.

•

Before re-assembling cartridge clean its housing with wet cloth and grease “O” rings on cartridge.

•

Re-assemble cartridge (8) into body and the extension (7).

•

Fit the screw (6) and chrome ring (5).

•

Fit the temperature stop ring (4) according to the drawing and turn spindle (A) until you reach required
temperature 38°C.

•

Fit the temperature control knob (3) and test that the maximum temperature is set at 43°C.

•

Fit the grub screw (2) and fit the lever (1).