Diverter cartridge change and cleaning

To clean the filters:

Shut off the water supply to both inlets

Remove the lever (1), remove the grub screw (2) with 2.5mm /

1

/

8

” Alan key, remove the closure con-

trol knob (3).

Remove the chrome ring (6).

Unscrew flange (7) using 17mm / i¾" spanner.

Remove the diverter cartridge (8).

Before re-assembling cartridge clean its housing with wet cloth and grease “O” rings on cartridge.

Place the new cartridge, inserting the two pivots into the corresponding seats.

Fit the flange (7).

Fit the chrome ring (6).

Fit the element (5) and the screw (4).

Fit the closure control knob (3).

Fit the grub screw (2) and fit the lever (1).