Diverter cartridge change and cleaning – Blu Bathworks TSP421 User Manual
Page 9
Advertising
![background image](/files/776247/content/doc009.png)
2013-07
1 866 907 0122 blubathworks.com
®
8
MAINTENANCE
Diverter cartridge change and cleaning
To clean the filters:
•
Shut off the water supply to both inlets
•
Remove the lever (1), remove the grub screw (2) with 2.5mm /
1
/
8
” Alan key, remove the closure con-
trol knob (3).
•
Remove the chrome ring (6).
•
Unscrew flange (7) using 17mm / i¾" spanner.
•
Remove the diverter cartridge (8).
•
Before re-assembling cartridge clean its housing with wet cloth and grease “O” rings on cartridge.
•
Place the new cartridge, inserting the two pivots into the corresponding seats.
•
Fit the flange (7).
•
Fit the chrome ring (6).
•
Fit the element (5) and the screw (4).
•
Fit the closure control knob (3).
•
Fit the grub screw (2) and fit the lever (1).
Advertising