Installation, Minimum clearance to combustible materials, Continued built-in fireplace installation – Desa CDCFPRA User Manual

Page 10

Advertising
background image

www.desatech.com

116658-01C

10

CAUTION: If you install the

fireplace in a home garage

• fireplace pilot and burner must

be at least 18" above floor.

• locate fireplace where moving

vehicle will not hit it.

For convenience and efficiency, install fireplace

• where there is easy access for operation, inspec-

tion, and service

• in coldest part of room

An optional blower kit is available from your

dealer. See Accessories, page 38. If planning to use

blower, follow instructions provided with blower

for power source.
Minimum Clearances For Side
Combustible Material, Side Wall and
Ceiling

A. Clearances from the side of the fireplace

cabinet to any combustible material and wall

should follow diagram in Figure 6.

Example: The face of a mantel, bookshelf,

etc. is made of combustible material and

protrudes 3

1

/

2

" from the wall. This combus-

tible material must be 4" from the side of the

fireplace opening (see Figure 6).

B. Clearances from the top of the fireplace opening

to the ceiling should not be less than 36 inches.

C. For mantel clearances, see Figure 10, page 12.

MINIMUM CLEARANCE TO

COMBUSTIBLE MATERIALS

Top

Left and

Right Sides

Bottom

and Rear

36"

6"

0"

Figure 6 - Minimum Clearance for

Combustible to Wall

*Minimum 16" from Side Wall

*

Example

iNsTallaTioN

Continued

bUILT-IN FIRePLACe
INSTALLATION

Built-in installation of this fireplace involves

installing fireplace into a framed-in enclosure.

This makes the front of fireplace flush with wall.

An optional brass trim kit accessory is available

(see Accessories, page 38). Brass trim will extend

past sides of fireplace approximately 1/2". This

will cover the rough edges of the wall opening.

If installing a built-in mantel above the fireplace,

you must follow the clearances shown in Figure 11,

page 12. Follow the instructions below to install

the fireplace in this manner.

Actual

Framing

Height

6"

6

7

/

8

"

Front Width

6

3

/

4

"

6

7

/

8

"

Depth

14

1

/

4

"

15

1

/

4

"

1. Frame in rough opening. Use dimensions

shown in Figure 7 for the rough opening. If

installing in a corner, use dimensions shown in

Figure 8 for the rough opening. The height is

26

7

/

8

" which is the same as the wall opening

above.

2. If installing GA3450TA blower accessory, do

so at this time. Follow instructions included

with blower accessory.

Note: If not installing blower accessory, you

may wish to run electrical wiring to your

fireplace for future blower installation (see

Accessories, page 38). Use only approved

three-wire electrical wiring.

Figure 8 - Rough Opening for Installing

in Corner

Figure 7 - Rough Opening for Installing

in Wall

43

5

/

16

"

30

5

/

8

"

61

1

/

4

"

26

7

/

8

"

26

7

/

8

"

26

7

/

8

"

3/4" Off
The Floor
Minimum

15

1

/

4

"