Installation – Desa CDCFPRA User Manual

Page 9

Advertising
background image

www.desatech.com

116658-01C



WARNING: Never install in a

bedroom or bathroom. Any heat-

ing product with a btu/Hr rating

over 10,000 cannot be used in a

bedroom.

CAUTION: This fireplace cre-

ates warm air currents. These

currents move heat to wall sur-

faces next to fireplace. Installing

fireplace next to vinyl or cloth

wall coverings or operating

fireplace where impurities (such

as, but not limited to, tobacco

smoke, aromatic candles, clean-

ing fluids, oil or kerosene lamps,

etc.) in the air exist, may discolor

walls or cause odors.

IMPORTANT:

Vent-free fireplaces add moisture to

the air. Although this is beneficial, installing fireplace

in rooms without enough ventilation air may cause

mildew to form from too much moisture. See Air for

Combustion and Ventilation, page 6.
Note:

Your fireplace is designed to be used in zero

clearance installations. Wall or framing material can be

placed directly against any exterior surface on the rear,

sides, or top of your fireplace, except where standoff

spacers are integrally attached. If standoff spacers are

attached to your fireplace, these spacers can be placed

directly against wall or framing materials.
Note:

When installing fireplace directly on carpet-

ing, tile or other combustible material, other than

wood flooring, the fireplace shall be installed on a

metal or wood panel extending the full width and

depth of the fireplace.

Use the dimensions shown for rough openings to

create the easiest installation (see Built-In Fire-

place Installation, page 10).

CHeCK GAS TyPe

Use the correct gas type (natural or propane/LP)

for your unit. If your gas supply is not correct, do

not install fireplace. Call dealer where you bought

fireplace for proper type fireplace.

iNsTallaTioN

Continued

WARNING: This appliance

is equipped for (natural or pro-

pane/LP) gas. Field conversion

is not permitted.

INSTALLATION ITEMS

Before installing fireplace, make sure you have

the items listed below.

• external regulator (supplied by installer, for

propane/LP units only)

• piping (check local codes)

• sealant (resistant to propane/LP gas)

• equipment shutoff valve *

• test gauge connection*

• ground joint union

• sediment trap

• tee joint

• pipe wrench

* A CSA design-certified equipment shutoff valve

with 1/8" NPT tap is an acceptable alternative to

test gauge connection. Purchase the optional CSA

design-certified equipment shutoff valve from your

dealer. See Accessories, page 38.
Note:

If desired, purchase a four-sided brass trim

kit for built-in installations. See Accessories,

page 38.

FIRePLACe CLeARANCeS

WARNING: Maintain the mini-

mum clearances shown in Figure

6, page 10. If you can, provide

greater clearances from floor,

ceiling, and joining wall.

If your fireplace is to be used with an optional

mantel, the installation instructions included with

your mantel shows an CSA approved method of

attaching the fireplace/mantel system to a wall.

IMPORTANT:

Only use optional cabinet or

corner mantels specified in this manual. Purchase

the optional mantel from your dealer (see Acces-

sories, page 38).

If your fireplace is to be recessed into the wall, see

Built-In Fireplace Installation, page 10, to secure

your fireplace into the wall.

Advertising