opERaTiNG FiREplaCE

Continued

ON/OFF SeRIeS (MODeL HRC100
SeRIeS)

Hold the control button on the hand-held remote

until burner turns on. Hold the control button

again until burner turns off (see Figure 43).

TO LOCK

press both buttons on hand-held

remote control until light stops flashing. Hand-

held remote control is now locked. If the fire is

on it will be turned off automatically. In the

locked state, the light will not light up when

any button is pressed.

TO UNLOCK

press both buttons together

on hand-held remote control until the light

stops flashing. The hand-held remote is now

unlocked.

THERMOSTAT SERIES (MODEL
HRC200 SeRIeS)

The hand-held remote can be operated using

either the manual mode (MANU) or thermo-

static mode (AUTO) (see Figure 44). To select

Fahrenheit/Centigrade mode display, carefully

press the ˚C/˚F mode button with the end of a

paper clip or similar blunt object.
Manual Mode

1. Press the POWER and LOCK buttons together

to turn on the hand-held remote control.

2. Press the MANU button to turn on the

fireplace.

3. Press the POWER and LOCK buttons

together to turn off the fireplace.

Auto (Thermostatic) Mode

1. Press the POWER and LOCK buttons together

to turn on the hand-held remote control.

2. Press AUTO button to select this mode.

3. Set the desired room temperature by press-

ing the TEMP + or - buttons.

4. Press the POWER and LOCK buttons

together to turn off the fireplace

Note:

Do not leave the hand-held remote in the

AUTO mode close to the fireplace. The radiant

heat from the fireplace will turn off the fireplace.

Ideally, place the hand-held remote in the center

of the room facing towards the fireplace.
Note:

Do not hold the hand-held remote for

a long time. Body temperature will affect its

operation in the AUTO mode.

Figure 43 - ON/OFF Hand-Held Remote

Control Unit

Control
Button

Indicator
Light

Figure 44 - Thermostat Hand-Held

Remote Control Unit

LOCK

MANU

AUTO

ºC/ºF

TEMP

POWER

ROOM
TEMP

SET
TEMP

AUTO

Turns
Hand-Held
Remote On
or Off and
Allows You
to Choose
the Manual
Setting

Selects
AUTO
Mode

°C/°F
Mode
Button

Locks
System to
Prevent
Accidental
Ignition

Turns
Burners
On or
Off

Increases or
Decreases
Room
Temperature
in AUTO Mode

Digital Display Shows
Temperature and Settings

Safety Features

When away from home for an extended period

of time or as a child safety feature to prevent

accidental ignition of the fireplace, the receiver

ON/OFF/REMOTE switch should be in the

OFF position.
Auto Shutoff Feature

1. If the average room temperature exceeds 82

degrees Fahrenheit (28 degrees Centigrade),

the hand-held remote control will perform a

safety override and shut the fireplace off. This

feature is not available in the MANU mode.

2. The receiver continuously receives signals

from the hand-held remote to control the

room temperature. If the hand-held remote

is misplaced, obstructed, or for any reason

cannot transmit to the receiver, the receiver

will shut off the fireplace after 8 minutes.