Owner’s manual, Operating heater, Inspecting burners – Desa FLAME-MAX UNVENTED (VENT-FREE) PROPANE/LP GAS LOG HEATER User Manual

Page 15: Cleaning and maintenance, Continued

Advertising
background image

15

104256

OWNER’S MANUAL

OPERATING
HEATER

Continued

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

1.

Press in and turn control knob clock-
wise

Clockwise

to the HIGH position.

2.

Turn the control knob clockwise

Clockwise

to the PILOT position.

3.

Press in control knob and turn clock-
wise

Clockwise

to the OFF Position.

Shutting Off Burners Only (pilot
stays lit)

1.

Turn the control knob clockwise

Clockwise

to the HIGH position.

2.

Press in and turn control knob clock-
wise

Clockwise

to the PILOT position.

INSPECTING
BURNERS

Check pilot flame pattern and burner flame
patterns often.

PILOT FLAME PATTERN

Figure 24 shows a correct pilot flame pat-
tern. Figure 25 shows an incorrect pilot
flame pattern. (

Note:

Appearance of pilot

assembly may vary by model.) The incor-
rect pilot flame is not touching the thermo-
couple. This will cause the thermocouple to
cool. When the thermocouple cools, the
heater will shut down.

Thermocouple

Pilot Burner

Figure 24 - Correct Pilot Flame Pattern

Pilot Burner

Thermocouple

Figure 25 - Incorrect Pilot Flame Pattern

If pilot flame pattern is incorrect, as shown
in Figure 25

• turn heater off (see To Turn Off Gas to

Appliance, column 1)

• see Troubleshooting, pages 16 through 18

MANUAL LIGHTING

PROCEDURE

WARNING: Do not operate

heater between PILOT and HIGH
positions.

CAUTION: Do not try to adjust

heating levels by using the
manual shutoff valve.

The variable control valve can be set to
any heat setting and flame height desired,
by simply turning the control knob until
that setting is attained. Even the lowest
setting provides realistic, dancing yellow
flames. Selecting higher settings produces
greater heat output. This results in in-
creased heating comfort.

VARIABLE CONTROL

OPERATION

1.

Follow steps 1 through 5 under Light-
ing Instructions
, page 14.

2.

Depress control knob and light pilot
with match.

3.

Keep control knob pressed in for 30
seconds after lighting pilot. After 30

seconds, release control knob. Now
follow step 8, page 14.

CLEANING AND
MAINTENANCE

WARNING: Turn off heater

and let cool before cleaning.

CAUTION: You must keep

control areas, burner, and circu-
lating air passageways of heater
clean. Inspect these areas of
heater before each use. Have
heater inspected yearly by a quali-
fied service person. Heater may
need more frequent cleaning due
to excessive lint from carpeting,
bedding material, etc.

ODS/PILOT AND BURNER

• Use a vacuum cleaner or small, soft

bristled brush to clean.

LOGS

• If you remove logs for cleaning, refer to

Installing Logs, page 13, to properly re-
place logs.

• Replace log(s) if broken or chipped

(dime-sized or larger).

Advertising