104256

OWNER’S MANUAL

SPECIFICATIONS

Golden Oak

Golden Oak

Vintage Oak

Vintage Oak

and Birch

and Birch

18" Variable

24" Variable

18" Variable

24”, 30”, and 36"

Manually

Manually

Manually

Variable

Controlled

Controlled

Controlled

Manually Controlled

Btu (Variable)

16,000/27,000

16,000/31,500

16,000/30,000

20,000/39,000

Type Gas

Propane Only

Propane Only

Propane Only

Propane Only

Ignition

Piezo

Piezo

Piezo

Piezo

Pressure Manifold

8.0" W.C.

8.0" W.C.

8.0" W.C.

8.0" W.C.

Inlet Gas Pressure (in. of water)

Maximum

14"

14"

14"

14"

Minimum*

11"

11"

11"

11"

* For input adjustment
Shipping Weight

27 lbs.

29 lbs.

28 lbs.

30 lbs. (24")/32 lbs. (30")
/34 lbs. (36”)

REPLACEMENT
PARTS

Note:

Use only original replacement parts.

This will protect your warranty coverage for
parts replaced under warranty.

Parts Under Warranty

Contact authorized dealers of this product.
If they can’t supply original replacement
part(s), call DESA International’s Techni-
cal Service Department at 1-800-323-5190.
When calling DESA International, have
ready

• your name and address

• model number of your heater

• how heater was malfunctioning

• type of gas used (propane or natural gas)

• purchase date

Usually, we will ask you to return the defec-
tive part to the factory.

Parts Not Under Warranty

Contact authorized dealers of this product.
If they can’t supply original replacement
part(s), call DESA International’s Parts
Department at 1-800-972-7879 for referral
information. When calling DESA Interna-
tional, have ready

• model number of your heater

• the replacement part number

ACCESSORIES

Purchase these heater accessories from your
local dealer. If they can not supply these
accessories, call DESA International’s Parts
Department at 1-800-972-7879 for referral
information. You can also write to the ad-
dress listed on the back page of this manual.

MANUAL SHUTOFF
VALVE - GA5010

For all models. Manual shutoff valve with 1/8"
NPT tap. Fits 1/2" NPT pipe.

SERVICE HINTS

When gas pressure is too low

• pilot will not stay lit

• burners will have delayed ignition

• heater will not produce specified heat

• propane/LP gas supply may be low

When gas quality is bad

• pilot will not stay lit

• burners will produce flames and soot

• heater will backfire when lit

You may feel your gas pressure is too low or
gas quality is bad. If so, contact your local
propane/LP gas supplier.

TECHNICAL
SERVICE

You may have further questions about in-
stallation, operation, or troubleshooting.

If so, contact DESA International’s Techni-
cal Service Department at

1-800-DESA LOG (1-800-337-2564).

BLACK FIREPLACE
HOOD - GA6050

For all models. Helps deflect heat away
from mantel or wall above fireplace. Fits
openings 28" to 48" wide.

BRASS FIREPLACE
HOOD - GA6052

For all models. Helps deflect heat away
from mantel or wall above fireplace. Fits
openings 28" to 48" wide.

DAMPER CLAMP - GA6080

For manually controlled models. Perma-
nently opens chimney flue damper for vented
operation.

LAVA ROCK - GA6060

For all models. Order when additional rock
is desired. (3 lb. bag)