CX-A850: Installation and Operation Manual

7

08-03-05 V4

15

Equalisation Module Installation

1. Turn the power off and remove the mains lead.
2. Remove the top panel from the unit.

Channel 7&8 PCB Connector Locations

3. Select the required PCB connector (see

Fig 12 adjacent) that you wish to install
the equalisation module to and remove
the jumper from it.

CON12 & J9 = Channel 1

CON13 & J10 = Channel 2

CON14 & J11 = Channel 3

CON15 & J12 = Channel 4

CON16 & J13 = Channel 5

CON17 & J14 = Channel 6

CON18 & J15 = Channel 7

CON19 & J16 = Channel 8

4. Configure the relevant 65Hz filter to ‘ON’ and connect a CXL-40T 100V line transformer

(see section 7)

5. Fit the EQ card to the connector such that the EQ card is perpendicular to the main board
6. Push down on the EQ card until it locates with a click.
7. Replace the top panel.

NOTE: Before installing active modules, check section 10 for details of the power supply on
the CX-A850. Each channel of the CX-A850 can have both a VCA-5 module and a speaker
EQ card installed at the same time.

16

Field Servicing

The CX-A850 is ruggedly built and uses proven reliable circuitry. It requires no more than the
occasional removal of any dust that may have built up inside the unit because of the forced
cooling.

17

General Specifications

Inputs

Balanced via 3-pin plug-in screw terminal type connectors

Outputs

2-pin plug-in screw terminal type connectors for flexible cables up to 2.5mm²

Protection

VI limiting, DC offset, Thermal, Switch-on Delay & Dynamic Clipping
Protection

Status Indicators

LED indicators on each channel for Signal, Peak &Protect

Cooling

Force cooled using variable speed DC fan

Dimensions

482.6mm x 88.0mm (2U) x 300.0mm deep (+ connectors)

Weight

8.8kgs