CX-A200 I

NSTALLATION AND OPERATION MANUAL

2

1

Safety Notes

The CX-A200 contains several PCB mounted jumpers which can be set to provide the
desired configuration for a specific venue or installation. These adjustments should be
performed by a technically qualified person who understands the hazards associated with
mains operated equipment. Do not remove the top panel unless you are qualified to do
so.

Remove the power cable from the unit before removing the top panel and do not make
any adjustments with the unit switched on.

The CX-A200 is supplied with a power cable fitted with a moulded plug. If the plug is cut
off the lead for any reason, remember that the discarded plug is a potential hazard and
should be disposed of in a responsible manner.

2

General

The CX-A200 is a four channel power amplifier with a maximum output of 50 watts per
channel into 4 ohm loads. The unit features extremely low distortion and low noise
together with a high slew rate. Full circuit protection is provided and the load is
disconnected if the heatsink overheats or any DC is detected at the output. A five second
switch-on delay operates to avoid any switching thumps or other extraneous signals
reaching the speaker system.

All four input amplifiers are balanced and connect via 3 pin XLR type connectors with
adjacent level controls, all mounted on the rear panel. Input signal routing jumpers are
provided and allow the unit to operate in many configurations whilst retaining simple input
connections.

The CX-A200 amplifier can be used with up to two optional plug-in two channel VCA
modules to provide remote level control. Each plug-in module can operate as two
individual attenuators with two remote level controls, or can be linked to operate as a
stereo pair with one remote level control.

3

Installation

The CX-A200 is suitable for mounting in a standard 19" equipment rack and occupies two
units of rack space. Sufficient ventilation must be provided for the unit. The amplifier
draws cool air through the front panel and exhausts through the back panel and care
must be taken not to obstruct the air flow otherwise the unit may intermittently turn off due
to the built-in thermal protection. The unit is 300mm deep but a depth of 375mm should
be allowed to clear the connectors.

Advertising