12 field servicing, 13 general specifications, 14 technical specifications – Cloud Electronics CXA200 User Manual

Page 8

Advertising
background image

CX-A200 I

NSTALLATION AND OPERATION MANUAL

7

12

Field Servicing

The CX-A200 is ruggedly built and uses proven reliable circuitry. It requires no more than
the occasional removal of any dust that may have built up inside the unit as a result of the
forced cooling. In the unlikely event of failure, the power amplifier module (4 channels)
complete with power supply components and input circuitry can be replaced without
special tools and is available as a tested replacement assembly complete with heatsink.
Proceed as follows to replace the power module:

Disconnect all the leads and connectors from the rear of the unit.
Ensure that the mains supply lead has been disconnected.
Remove the CX-A200 from the equipment rack.
Remove the top panel.
Remove the 10 way ribbon cable and the four spade terminal which connect the
transformer. Disconnect the red and black fan supply wires.
Remove the VCA modules (if fitted) complete with the mounting spacers.
Remove the eight fixing screws from the input connectors and the two fixing screws from
the output connectors. Now remove the PCB fixing screws and carefully remove the PCB
Now fit the replacement unit by proceeding in reverse order.
No setting up is required and the unit should operate normally.

13

General Specifications

Inputs

Balanced via 3 pin XLR type connectors

Outputs

Binding Posts for flexible cables up to 2.5mm²

Protection

VI limiting, DC offset, Thermal and Switch-on Delay

Status Indicators

LED indicators on each channel for Signal, Peak &Protect

Cooling

Force cooled using three speed DC fan

Dimensions

482.6mm x 88.0mm (2U) x 300.0mm deep (+ connectors)

Weight

6kg net

14

Technical Specifications

Rated output

50 watts/4 ohm load 35 watts/8 ohm load

Bridged Output

100 watts/8 ohm load

Frequency Response

±1dB 10Hz to 50kHz

THD

<0.05% 20Hz/20kHz 8 1dB below rated output

VCA Module THD

<0.03% 20Hz/20kHz

Input Sensitivity

0dBu (775mV)

Input Impedance

10k balanced / 5k unbalanced

Noise

>90dB below rated output

Slew Rate

10V/µS (power amplifier)

Power Input

230V ±5% (115V ±5% available)

Fuse rating

230V - T3.15A 115V - T6.3A

Fuse type

20mm x 5mm class 3T 250V